Below are the Transition Networks ION Platform stand alone devices available from Gen-X IT. For pricing and more information, please contact our Transition Networks product specialist Graeme Sutton on +44 (0) 1691 680 830 or email him directly by clicking >>here<<.
DS3 – T3/E3 Coax to Fiber Network Interface Device
DS3 – T3/E3
| Product Number | Port One | Port Two |
| 1) S6210-3011 | (2) Coax (BNC) | 1300nm multimode (ST) [2 km/1.2 mi.] |
| 2) S6210-3013 | (2) Coax (BNC) | 1300nm multimode (SC) [2 km/1.2 mi.] |
| 3) S6210-3014 | (2) Coax (BNC) | 1310nm single mode (SC) [20 km/12.4 mi.] |
| 4) S6210-3015 | (2) Coax (BNC) | 1310nm single mode (SC) [40 km/24.9 mi.] |
| 5) S6210-3016 | (2) Coax (BNC) | 1310nm single mode (SC) [60 km/37.3 mi.] |
| 6) S6210-3017 | (2) Coax (BNC) | 1550nm single mode (SC) [80 km/49.7 mi.] |
| 7) S6210-3029-A1 | (2) Coax (BNC) | 1310nm TX/1550nm RX single fiber single mode (SC) [20 km/12.4 mi.] |
| 8) S6210-3029-A2 | (2) Coax (BNC) | 1550nm TX/1310nm RX single fiber single mode (SC) [20 km/12.4 mi.] |
| 9) S6210-3029-B1 | (2) Coax (BNC) | 1310nm TX/1550nm RX single fiber single mode (SC) [40 km/24.9 mi.] |
| 10) S6210-3029-B2 | (2) Coax (BNC) | 1550nm TX/1310nm RX single fiber single mode (SC) [40 km/24.9 mi.] |
| 11) S6210-3040 | (2) Coax (BNC) | SFP Slot (empty) |
10/100/1000BASE-T to 100BASE-FX
OAM/IP-Based Remotely Managed NID
| Product Number | Port One | Port Two |
| 12) S2220-1011 | 10/100/1000BASE-T (RJ-45) [100 m/328 ft.] | 100BASE-FX 1310nm multimode (ST) [2 km/1.2 mi.] |
| 13) S2220-1011-D | 10/100/1000BASE-T (RJ-45) [100 m/328 ft.] | 100BASE-FX 1310nm multimode (ST) [2 km/1.2 mi.] |
| 14) S2220-1013 | 10/100/1000BASE-T (RJ-45) [100 m/328 ft.] | 100BASE-FX 1310nm MM (SC) [2 km/1.2 mi.] |
| 15) S2220-1013-D | 10/100/1000BASE-T (RJ-45) [100 m/328 ft.] | 100BASE-FX 1310nm MM (SC) [2 km/1.2 mi.] |
| 16) S2220-1014 | 10/100/1000BASE-T (RJ-45) [100 m/328 ft.] | 100BASE-LX 1310nm SM (SC) [10 km/6.2 mi.] |
| 17) S2220-1014-D | 10/100/1000BASE-T (RJ-45) [100 m/328 ft.] | 100BASE-LX 1310nm SM (SC) [10 km/6.2 mi.] |
| 18) S2220-1015 | 10/100/1000BASE-T (RJ-45) [100 m/328 ft.] | 100BASE-FX 1310nm SM (SC) [40 km/24.8 mi.] |
| 19) S2220-1015-D | 10/100/1000BASE-T (RJ-45) [100 m/328 ft.] | 100BASE-FX 1310nm SM (SC) [40 km/24.8 mi.] |
| 20) S2220-1016 | 10/100/1000BASE-T (RJ-45) [100 m/328 ft.] | 100BASE-FX 1550nm SM (SC) [60 km/37.3 mi.] |
| 21) S2220-1017 | 10/100/1000BASE-T (RJ-45) [100 m/328 ft.] | 100BASE-FX 1550nm SM (SC) [80 km/49.7 mi.] |
| 22) S2220-1029-A1 | 10/100/1000BASE-T (RJ-45) [100 m/328 ft.] | 100BASE-BX-U 1310nm TX/1550nm RX Bi-Di SM (SC) [20 km/12.4 mi.] |
| 23) S2220-1029-A2 | 10/100/1000BASE-T (RJ-45) [100 m/328 ft.] | 100BASE-BX-D 1550nm TX/1310nm RX Bi-Di SM (SC) [20 km/12.4 mi.] |
| 24) S2220-1029-B1 | 10/100/1000BASE-T (RJ-45) [100 m/328 ft.] | 100BASE-BX-U 1310nm TX/1550nm RX Bi-Di SM (SC) [40 km/24.8 mi.] |
| 25) S2220-1029-B2 | 10/100/1000BASE-T (RJ-45) [100 m/328 ft.] | 100BASE-BX-D 1550nm TX/1310nm RX Bi-Di SM (SC) [40 km/24.8 mi.] |
| 26) S2220-1029-DA1 | 10/100/1000BASE-T (RJ-45) [100 m/328 ft.] | 100BASE-BX-U 1310nm TX/1550nm RX Bi-Di SM (SC) [20 km/12.4 mi.] |
| 27) S2220-1029-DA2 | 10/100/1000BASE-T (RJ-45) [100 m/328 ft.] | 100BASE-BX-D 1550nm TX/1310nm RX Bi-Di SM (SC) [20 km/12.4 mi.] |
| 28) S2220-1035 | 10/100/1000BASE-T (RJ-45) [100 m/328 ft.] | 100BASE-FX 1550nm SM (SC) [120 km/77.7 mi.] |
| 29) S2220-1040 | 10/100/1000BASE-T (RJ-45) [100 m/328 ft.] | 100Base-X Open SFP Slot |
T1/E1 to Fiber Network Interface Device
T1/E1 to Fiber
| Product Number | Port One | Port Two |
| 30) S6010-1011 | Twisted Pair (RJ-48) [1.5 km/0.9 mi.] | 1300nm multimode (ST) [2 km/1.2 mi.] |
| 31) S6010-1013 | Twisted Pair (RJ-48) [1.5 km/0.9 mi.] | 1300nm multimode (SC) [2 km/1.2 mi.] |
| 32) S6010-1014 | Twisted Pair (RJ-48) [1.5 km/0.9 mi.] | 1310nm single mode (SC) [20 km/12.4 mi.] |
| 33) S6010-1015 | Twisted Pair (RJ-48) [1.5 km/0.9 mi.] | 1310nm single mode (SC) [40 km/24.9 mi.] |
| 34) S6010-1016 | Twisted Pair (RJ-48) [1.5 km/0.9 mi.] | 1310nm single mode (SC) [60 km/37.3 mi.] |
| 35) S6010-1017 | Twisted Pair (RJ-48) [1.5 km/0.9 mi.] | 1550nm single mode (SC) [80 km/49.7 mi.] |
| 36) S6010-1029-A1 | Twisted Pair (RJ-48) [1.5 km/0.9 mi.] | 1310nm TX/1550nm RX single fiber single mode (SC) [20 km/12.4 mi.] |
| 37) S6010-1029-A2 | Twisted Pair (RJ-48) [1.5 km/0.9 mi.] | 1550nm TX/1310nm RX single fiber single mode (SC) [20 km/12.4 mi.] |
| 38) S6010-1029-B1 | Twisted Pair (RJ-48) [1.5 km/0.9 mi.] | 1310nm TX/1550nm RX single fiber single mode (SC) [40 km/24.9 mi.] |
| 39) S6010-1029-B2 | Twisted Pair (RJ-48) [1.5 km/0.9 mi.] | 1550nm TX/1310nm RX single fiber single mode (SC) [40 km/24.9 mi.] |
| 40) S6010-1040 | Twisted Pair (RJ-48) [1.5 km/0.9 mi.] | SFP Slot (empty) |
| 41) S6010-3040 | (2) Coax (BNC) | SFP Slot (empty) |
10/100/1000BASE-T to 1000BASE-SX/LX
OAM/IP-Based Remotely Managed NID
| Product Number | Port One | Port Two |
| 42) S3230-1013 | 10/100/1000BASE-T (RJ-45) [100 m/328 ft.] | 1000BASE-SX 850nm multimode (SC) [62.5/125 µm: 300 m/984 ft.; 50/125 µm: 550 m/1804 ft.] |
| 43) S3230-1013-D | 10/100/1000BASE-T (RJ-45) [100 m/328 ft.] | 1000BASE-SX 850nm multimode (SC) [62.5/125 µm: 300 m/984 ft.; 50/125 µm: 550 m/1804 ft.] |
| 44) S3230-1014 | 10/100/1000BASE-T (RJ-45) [100 m/328 ft.] | 1000BASE-LX 1310nm single mode (SC) [30 km/18.6 mi.] |
| 45) S3230-1014-D | 10/100/1000BASE-T (RJ-45) [100 m/328 ft.] | 1000BASE-LX 1310nm single mode (SC) [30 km/18.6 mi.] |
| 46) S3230-1015 | 10/100/1000BASE-T (RJ-45) [100 m/328 ft.] | 1000BASE-LX 1310nm single mode (SC) [30 km/18.6 mi.] |
| 47) S3230-1015-D | 10/100/1000BASE-T (RJ-45) [100 m/328 ft.] | 1000BASE-LX 1310nm single mode (SC) [30 km/18.6 mi.] |
| 48) S3230-1017 | 10/100/1000BASE-T (RJ-45) [100 m/328 ft.] | 1000BASE-ZX 1550nm single mode (SC) [80 km/49.7 mi.] |
| 49) S3230-1029-A1 | 10/100/1000BASE-T (RJ-45) [100 m/328 ft.] | 1000BASE-BX-U 1310nm TX/1490nm RX Bi-Di single mode (SC) [20 km/12.4 mi.] |
| 50) S3230-1029-A2 | 10/100/1000BASE-T (RJ-45) [100 m/328 ft.] | 1000BASE-BX-D 1490nm TX/1310nm RX Bi-Di single mode (SC) [20 km/12.4 mi.] |
| 51) S3230-1029-B1 | 10/100/1000BASE-T (RJ-45) [100 m/328 ft.] | 1000BASE-BX-U 1310nm TX/1490nm RX Bi-Di single mode (SC) [40 km/24.8 mi.] |
| 52) S3230-1029-B2 | 10/100/1000BASE-T (RJ-45) [100 m/328 ft.] | 1000BASE-BX-D 1490nm TX/1310nm RX Bi-Di single mode (SC) [40 km/24.8 mi.] |
| 53) S3230-1029-DA1 | 10/100/1000BASE-T (RJ-45) [100 m/328 ft.] | 1000BASE-BX-U 1310nm TX/1490nm RX Bi-Di single mode (SC) [20 km/12.4 mi.] |
| 54) S3230-1035 | 10/100/1000BASE-T (RJ-45) [100 m/328 ft.] | 1000BASE-ZX 1550nm single mode (SC) [120 km/77.7 mi.] |
| 55) S3230-1040 | 10/100/1000BASE-T (RJ-45) [100 m/328 ft.] | 100/1000BASE-X SFP Slot (empty) |
| 56) S3253-NA | (4) SFP ports (100 Mbps, 1000 Mbps, or 10/100/1000 Mbps copper SFP) (1) 10/100BASE-TX (RJ-45) [100 m] |
10/100/1000Base-T
OAM/IP-Based Remotely Managed NID
| Product Number | Port One | Port Two |
| 57) S3220-1013 | 10/100/1000BASE-T (RJ-45) [100 m/328 ft.] | 1000BASE-SX 850nm multimode (SC) [62.5/125 µm: 220 m/722 ft.; 50/125 µm: 550 m/1804 ft.] |
| 58) S3220-1013-D | 10/100/1000BASE-T (RJ-45) [100 m/328 ft.] | 1000BASE-SX 850nm multimode (SC) [62.5/125 µm: 220 m/722 ft.; 50/125 µm: 550 m/1804 ft.] |
| 59) S3220-1014 | 10/100/1000BASE-T (RJ-45) [100 m/328 ft.] | 1000BASE-LX 1310nm single mode (SC) [10 km/6.2 mi.] |
| 60) S3220-1014-D | 10/100/1000BASE-T (RJ-45) [100 m/328 ft.] | 1000BASE-LX 1310nm single mode (SC) [10 km/6.2 mi.] |
| 61) S3220-1015 | 10/100/1000BASE-T (RJ-45) [100 m/328 ft.] | 1000BASE-LX 1310nm single mode (SC) [30 km/18.6 mi.] |
| 62) S3220-1015-D | 10/100/1000BASE-T (RJ-45) [100 m/328 ft.] | 1000BASE-LX 1310nm single mode (SC) [30 km/18.6 mi.] |
| 63) S3220-1017 | 10/100/1000BASE-T (RJ-45) [100 m/328 ft.] | 1000BASE-ZX 1550nm single mode (SC) [80 km/49.7 mi.] |
| 64) S3220-1029-A1 | 10/100/1000BASE-T (RJ-45) [100 m/328 ft.] | 1000BASE-BX-U 1310nm TX/1490nm RX Bi-Di single mode (SC) [20 km/12.4 mi.] |
| 65) S3220-1029-A2 | 10/100/1000BASE-T (RJ-45) [100 m/328 ft.] | 1000BASE-BX-D 1490nm TX/1310nm RX Bi-Di single mode (SC) [20 km/12.4 mi.] |
| 66) S3220-1029-B1 | 10/100/1000BASE-T (RJ-45) [100 m/328 ft.] | 1000BASE-BX-U 1310nm TX/1490nm RX Bi-Di single mode (SC) [40 km/24.8 mi.] |
| 67) S3220-1029-B2 | 10/100/1000BASE-T (RJ-45) [100 m/328 ft.] | 1000BASE-BX-D 1490nm TX/1310nm RX Bi-Di single mode (SC) [40 km/24.8 mi.] |
| 68) S3220-1029-DA1 | 10/100/1000BASE-T (RJ-45) [100 m/328 ft.] | 1000BASE-BX-U 1310nm TX/1490nm RX Bi-Di single mode (SC) [20 km/12.4 mi.] |
| 69) S3220-1029-DA2 | 10/100/1000BASE-T (RJ-45) [100 m/328 ft.] | 1000BASE-BX-D 1550nm TX/1310 m RX Bi-Di single fiber single mode (SC) [20 km/12.4 mi.] |
| 70) S3220-1035 | 10/100/1000BASE-T (RJ-45) [100 m/328 ft.] | 1000BASE-ZX 1550nm single mode (SC) [120 km/77.7 mi.] |
| 71) S3220-1040 | 10/100/1000BASE-T (RJ-45) [100 m/328 ft.] | 100/1000BASE-X SFP Slot (empty) |
| 72) S3221-1040 | 10/100/1000BASE-T (RJ-45) [100 m/328 ft.] | 100/1000BASE-X SFP Slot (empty) |
Remotely Managed NID (Network Interface Device)
3) 10/100/1000BASE-T (RJ-45) [100 m] to (2) 100/1000Base-X Open SFP Slots
| Product Number | Port One | Port Two |
| 73) S3240 | (3) 10/100/1000BASE-T (RJ-45) [100 m/328 ft.] | (2) 100/1000BASE-X SFP Slot (empty) |